Seating configuration is stadium
style, 14 rows deep on 15 " risers separated
by two stepped aisles from the main transverse aisle
or "promenade". Seating configuration
mirrors the semi-thrust shape of the stage.
There are box seat locations on
both sides of the house.
Maximum distance from stage is less
than 45 feet.
Handicapped accessible.
Accommodations for one wheelchair patron.
Infra-red assisted listening system available.
House lighting powered via 100A panel
and programmable electronic dimming system. Control
located in control booth House Right.
The theatre is fully sprinklered.
Standpipe connections on all levels. Fire Alarm
pull stations throughout.
Auditorium's Theatre
Technology Features:
- Follow spot platforms at top of house.
- Control booths behind seating at sides,
near top of house.
- Electrics control House Right.
- Audio control House Left.
- Stage Management can share either
position.
- Ladder access to booths as well as
entrance from Row P
- Vertical lighting boom positions on
both sides of the House behind and above Box Seats
and in front of Control Booths.
- Floor outlets in seating at center
to accommodate tech tables behind row E and at top
of House in Row P.
- Various work lighting independent
of house lights
Semi - thrust stage. Combination of permanent
knee wall construction upstage and removable platforms
downstage. Reference line defines these sections
at 11 ' - 0 " from downstage edge
of deck at CL.
Center Line ( CL ) defined by architectural
proscenium 24 ' - 1 1/2 " from CL
to proscenium arch.
- Proscenium opening width = 48 '
- 3 " @ architectural proscenium
- Stage width = 48 ' - 9 "
@ downstage of proscenium
- Width of stage @ downstage edge
= 14 ' - 10 "
- Length of stage right edge of stage
= 19 ' - 3 "
- Length of stage left edge of stage
= 19 ' - 5 "
- Depth from reference line to down
stage, most off stage point = 1 ' - 7 "
- Downstage edge of apron to reference
line at CL = 11 '- 0 "
- Unobstructed useable stage depth
from reference line to back wall = 12 ' -
7 "
- Overall width of stage = 56 '
(see groundplan for Trash Chute U.S.R.)
- There is no appreciable usable wing
space.
- Entrances can be made from Upstage
Left and Downstage Right
- There is no built-in cross-over
upstage or under the stage.
- Crossover possible through the Lobby
- Orchestra pit can be constructed
onstage; with removal of sections of the stage,
and on either side of the house with the removal
of portions of the Box Seat Locations.
Stage Deck:
Upstage ( permanent ) construction:
Cross-braced knee walls running left to right .
2 X 4 framed knee walls with double layer of 3/4
" plywood and triple layer of 1/4 "
mesonite . Crawl space for cable runs under the
stage approximately 41 " high and 36 "
wide. Access from both side of the stage and from
downstage area.
Downstage ( removable ) construction:
Platforms of various shapes and sizes, most 4 '
X 8 ' near center; constructed of 2 X 6 frames
topped with single layer of 3/4" plywood and
double layer of 1/4 " mesonite. Supported
by steel frame leg structure bolted together and
to the permanent upstage portion of the stage. With
platforms removed, there is a clear height from
the floor to the stage level of 69 ".
Rigging Accommodations:
- No system lines, blocks, counterweight
carriages, etc. currently available
- Under-hung static grid of 1-1/2
" schedule 40 steel pipe
- Grid height = 21 ' - 9 "
deck to bottom of pipe
- Bottom of I-beams to deck = 22 '
- 0 "
- Cable Run located approximately
6 ' - 0 " upstage of reference line
Electric Power Availability (all distribution
is 120/208V 3-phase)
Main power distribution located in
Dimmer Room beneath the stage. Freight elevator
access for dimmers and amp racks 26 " wide.
- 400A Lighting tie-in with Cam-Lok
tails located in Dimmer Room beneath the stage.
- 100A Sound tie-in with Cam-Lok tails
located in Dimmer Room beneath the stage.
- 100A fused disconnect at stage level
for automation, projection, etc.
- 200A fused disconnect in hallway
to 76th St. for remote T.V. truck, automation, etc.
- 15A courtesy quad boxes located
upstage of proscenium arch on each side of the stage
for running lights, etc.
Fire Safety
- Fire alarm system emergency control
panel located in Dimmer Room. Ionization type smoke
detectors used in Air Conditioning ducts above the
stage.
- * !!! FIRE ALARM SYSTEM
ANNUNCIATES THROUGHOUT ENTIRE BUILDING WHEN ACTIVATED
!!!! USE OF THEATRICAL SMOKE, HAZE, FOG,etc. MUST
BE APPROVED BY PROMENADE TECHNICAL DIRECTOR BEFORE
USE. !!!! *
- Mechanical smoke exhaust system
interfaced with fire alarm system but also available
for general ventilation.
- Stagehouse is fully sprinklered.
Standpipe connections on all levels. Fire Alarm
pull stations throughout.
1.) STAGE RIGHT:
Single room with adjacent seating
/ office area for featured performer located off-stage
right with adjacent bathroom with shower. Isolated
area with direct access to entrance stage right
and to Lobby. Can also be used as Stage Management
Office, Props, Wardrobe/ Quick Change area. 2 telephone
jacks installed. Air conditioned.
2.) STAGE LEFT :
3 rooms located one, two, and three
floors above street level.
Second
Floor : 2 rooms with sink in common
area and shower on this level.
Larger room has 10 stations with
individual mirrors with vanity lights, one telephone
jack, and air conditioning. Windows to 76th St.
Smaller room has 7 stations with
individual mirrors with vanity lights, two telephone
jacks, and air conditioning. This room can also
be used as a Stage Management Office.
Third
Floor : One large room with Men's
and Ladies restrooms on this level.
Large room has 11 stations with individual
mirrors with vanity lights, one telephone jack,
and air conditioning. Windows to 76th St. . Restrooms
on this level.
Fourth
Floor : Wardrobe room with laundry facilities.
Washer, vented dryer, sewing machine, iron, ironing
board, and steamer. Work table for laundry. Eight
stations with individual mirrors with vanity lights.
Separate full bathroom with tub and shower. Air
conditioned.
Load-in facilities (stage
level is 5 ' - 6 " above street level):
Load- in from 76th St. Hallway from
street to Green Room. Smallest opening is doorway
from Hallway to Green Room at 34 -1/2 " wide
X 80 -1/4 " high. Direct access to stagehouse
at downstage left via opening of 49 - 1/2 "
wide and 84 " high. Portions of the front row,
seats and flooring, as well as portions of the stage
can be removed in order to accommodate the installation
of large scenery pieces. SITE SURVEY OF LOAD-IN PATH
BEFORE CONSTRUCTION OF SCENIC ELEMENTS HIGHLY
RECCOMENDED !!!!!
Top
of Page
|
|
|
 |
|
|
 |